Cat C15 Generator Set

Minimum Rating 365 kVA

Maximum Rating 550 kVA

Emissions/Fuel Strategy Tier 2 or Tier 3

The C15 diesel generator sets have been developed for your mission critical, standby and prime applications. Producing reliable power from 365 to 550 kVA at 50 Hz, meeting ISO 8528-5 transient response requirements and built to accept 100 percent rated load in one step. The engines are certified Low Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 or Tier 3 Nonroad Equivalent Emission Standards), EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards Emissions / Fuel Strategy.

Feature Image
Cat Generator Set Package

Cat generator set packages have been fully prototype testedAccepts 100% block load in one step and meets NFPA 110 loading requirem…

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
MORE DETAILS
Feature Image
Cat Diesel Engine

Reliable, rugged, durable designField-proven in thousands of applications worldwideFour-stroke-cycle diesel engine combines consis…

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
MORE DETAILS
Feature Image
A-Frame Alternator

Superior motor starting capability minimizes need for oversizing alternatorDesigned to match performance and output characteristic…

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
MORE DETAILS
Feature Image
EMCP Control Panel

User-friendly interface and navigationScalable system to meet a wide range of installation requirementExpansion modules and site-s…

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
MORE DETAILS
Feature Image
Cooling System

Designed to operate in standard ambient temperatures up to 55°C (131°F)Contact your Cat Dealer for specific ambient and altitude c…

  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
MORE DETAILS
Feature Image
One Safe Source

Components used in the generator set are selected based on seamless design integration to provide the optimum performanceThe gener…

  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
MORE DETAILS
Feature Image
World Wide Product Support

Cat dealers have over 1,800 dealer branch stores operating in 200 countriesYour local Cat dealer provides extensive post-sale supp…

  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
MORE DETAILS

Standard Equipment

Air System
  • Turbocharger
  • Aftercooler core
  • Air Cleaner - Non Canister disposable paper filter
Air Inlet
  • Air Cleaner
Control Panel
  • EMCP 4.2
Cooling
  • Package mounted radiator
Cooling System
  • Caterpillar Extended Life Coolant
  • Radiator and cooling fan with guard
  • Fan drive, battery charging alternator drive
  • Coolant drain line with valve
Exhaust
  • Base, formed steel with single wall integral 8-hour fuel tank
  • Standard open set fuel tank / base supplied
Fuel
  • Primary fuel filter with integral water separator
  • Secondary fuel filter
  • Fuel priming pump
Fuel System
  • Engine fuel transfer pump
  • Primary fuel filter w/integral water separator & secondary filter
  • Fuel priming pump
  • Flexible fuel lines
  • Fuel cooler
Generator
  • Matched to the performance and output characteristics of Cat engines
  • IP23 Protection
  • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
Power Termination
  • Bus Bar
Generator and Attachments
  • Mandatory Option circuit breaker, IEC, 3 pole, mounted in power centre
  • Optional LC frame generator - IP23 Protection
  • Segregated low voltage (AC/DC) wiring panel
  • Integrated Voltage Regulator
  • Power center, IP22
Mounting
  • Rubber vibration isolators
Governing System
  • Cat Electronic Governor (ADEM A4).
Lube System
  • Oil cooler
  • Oil drain valves
Mounting System
  • Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines
Starting/Charging
  • 24 Volt battery with rack and cables
General
  • Engine and alternator pre paint, Caterpillar yellow
Air Inlet System
  • Single element air cleaner
  • Dual element air cleaner
Exhaust
  • Industrial, Residential, Critical Mufflers
Certifications
  • EU certificate of conformance
  • Global certification for CIS
Generator
  • Excitation: [ ] Permanent Magnet Excited (PM) [ ] Internally Excited (IE)
  • Oversize and premium generators
  • Anti-condensation heater
Power Termination
  • Circuit breakers, UL listed
  • Circuit breakers, IEC compliant
Circuit breakers
  • Shunt trip for IEC circuit breaker
  • 4 Pole (IEC-100% rated) circuit breakers - Package mounted
  • Auxiliary contacts, circuit breaker
  • 3 Pole (IEC-100% rated) circuit breakers - Package mounted
  • 3 Pole (IEC-100% rated) circuit breakers - Motorised
  • Power terminal strip
  • 4 Pole (IEC-100% rated) circuit breakers - Motorised
  • Pad-lockable circuit breaker device
Generator and Attachments
  • Permanent magnet generator
  • LC frame CIP generator
  • Oversize LC frame generator
  • Space heaters
  • CIP a frame generator
  • Oversize A frame generator
  • Ingress protection
  • A frame generator - IP21 Protection
  • LC frame generator
Control Panels
  • Fuel level sensor
  • Volt free contacts
  • Oil temperature displays
  • Local annunciator
  • EMCP 4.3, EMCP 4.4
  • Local alarm horn
  • Remote annunciator
Starting/Charging
  • Oversize batteries
  • Battery chargers
  • Jacket water heater
  • Heavy-duty starting system
  • Charging alternator
Cooling System
  • Low coolant temperature alarm
  • Stone guards
  • Radiator duct flange
General
  • Narrow, Wide or Skid Base
  • Single or dual wall integral fuel tanks
  • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
  • The following options are based on regional and product configuration:
  • Automatic transfer switches (ATS)
  • Integral & sub-base UL listed dual wall fuel tanks
  • CSA Certification
  • EEC Declaration of Conformity
  • Single or dual wall sub-base fuel tanks
  • UL 2200 package
  • Sound attenuated, weather protective or high ambient weather protective enclosure
  • EU Certificate of Conformance (CE)
Enclosures
  • High ambient sound attenuated enclosures
  • Sound attenuated enclosures
Exhaust System
  • 6 and 8 inch elbow kit
  • Manifold and turbocharger guard
  • End in / End out mufflers - 10, 25 and 35 dBA attenuation
  • Engine mounted muffler
  • 6 and 8 inch flange GP
  • Flexible exhaust fittings
Fuel System
  • Fuel transfer system controls
  • Manual fuel transfer pump
  • Dual wall fuel tank base
Lube System
  • Manual sump pump
Mounting System
  • Narrow skid base - replaces standard fuel tank base
Special Test / Reports
  • PGS Test report @ 1.0 power factor
  • PGS Test report @ 0.8 power factor
Starting / Charging System
  • 5 Amp single battery charger
  • Jacket water heater
  • Battery disconnect switch

Technical Specifications

  • Generator Set Specifications
    Minimum Rating 365 kVA
    Maximum Rating 550 kVA
    Emissions/Fuel Strategy Tier 2 or Tier 3
    Voltage 208 to 600 Volts
    Frequency 50 Hz
    Speed 1500 rpm
    Duty Cycle Standby, Prime
  • Engine Model C15 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
    Bore 5.4 in
    Stroke 6.75 in
    Displacement 927.56 in³
    Compression Ratio 16.1:1
    Aspiration Air to Air Aftercooled
    Fuel System MEUI
    Governor Type Adem™A4
  • Length - Maximum 150.8 in
    Width - Maximum 58.3 in
    Height - Maximum 86.3 in

Frequently Compared Machines

See how this model compares against similar machines to find the perfect match.

Service Solutions

We have an extensive team of experts to help you enhance every aspect of your operations.

Warranty & Guarantee
Warranty & Guarantee
Rest assured. When you buy a Cat® machine or power system from Mantrac, it comes with industry-leading warranties and world-class administration support.
Technology
Technology
Mantrac provides cutting-edge Cat® technology to help you keep your jobsite connected, reducing the risk of downtime while enhancing productivity and profitability.
Financing
Financing
We provide flexible financing options, because we know our products and services have great potential to boost your profitability.